Subject: | |
From: | |
Reply To: | The Museum System (TMS) Users |
Date: | Mon, 28 Aug 2006 13:36:48 -0400 |
Content-Type: | multipart/alternative |
Parts/Attachments: |
|
|
Yes, the upgrade to 9.2 certainly has its set of issues. Gallery systems
provided a batch file which registered .dlls that didn't get registered
during the original installation. Some of these .dlls related to the
export function and running the TMS client. We were also told to use the
server install on clients instead of the workstation client and that
helped significantly.
The export feature .dlls is the only fix I have right now. Hope this
helps.
Run from command line or create batch file:
regsvr32 "%Windir%\System32\atl.dll"
regsvr32 "%Windir%\System32\crtslv.dll"
regsvr32 "%Windir%\System32\exportmodeller.dll"
-Dwight
----------------------------------------------
Dwight Bailey
Samuel P. Harn Museum of Art
www.harn.ufl.edu <http://www.harn.ufl.edu/>
SW 34th Street and Hull Road
PO Box 112700
Gainesville, FL 32611-2700
P: 325 392 9826 x155
F: 352 392 3792
[log in to unmask]
----------------------------------------------
________________________________
From: The Museum System (TMS) Users [mailto:[log in to unmask]]
On Behalf Of Danna, Cheryl
Sent: Monday, August 28, 2006 1:17 PM
To: [log in to unmask]
Subject: Help TMS Client Intsall
We are trying to upgrade to 9.22 and are having a terrible time with the
client installation. The server installation was bad enough but the
client is terrible. The instructions we have received from Gallery have
not been complete we have been trying for almost a week. From what we
can tell there is a problem with .dll files being registered for the
plug ins. Has any one else had this type of problem.
Thanks.
Cheryl M. Danna
Business Analyst
City of Tempe
Information Technology Department
Application Services
Tempe, Arizona 85281
Phone: 480-350-5038
Fax: 480-350-5055
|
|
|